Double _ Beam
Double-Beam UV/Visible Spectrophotometer

The Phoenix-2200DPCV is the top of the range of our UV/Visible spectrophotometers. It is a Double-Beam Ratio Recording instrument with high performance and resolution thanks to its advanced optical system. It is a computer controlled spectrophotometer which comes with its dedicated UV-WIN Windows-based software for commanding the fuctions of the instrument and its accessories from a PC and for data collection and management.
We have recently introduced an identical model, the Phoenix-2200DPC which has exactly all the same features as the above with a minor variation in the specifications whereas the bandpass is a fixed 2nm instead of being variable in 6 values down to 0.1nm. The price of the Phoenix-2200DPC is sensitively lower than the Phoenix-2200DPCV.
.
A wide and comprehensive range of accessories for routine and/or special applications is available upon demand. For further information, please apply to your nearest distributor or call our products specialists.
SPECIFICATIONS
Hardware:
1. Wavelength Range : 190-900 nm
2. Spectral Bandwidth: Variable for the Phoenix-2200DPCV at 0.1, 0.2, 0.5, 1.0, 2.0, 5.0nm
Fixed for the Phoenix-2200DPC at 2nm.
3. Wavelength Accuracy: +0.3nm(automatic wavelength correction)
4.Wavelength-Reproducibility: 0.1nm
5.Photometric Accuracy: +0.002Abs(0-0.5Abs), +0.004Abs(0.5- 1.0Abs), +0.3%T(0-100%T)
6.Photometric-Reproducibility: +0.001Abs
7.Stray Light : 0.02%(at 220nm 10g/l NaI aq.)
8.Baseline Flatness: +0.001Abs
9. Noise : < 0.0004Abs (at 500nm,with bandwidth 2nm)
10.Stability : 0.0004Abs (2 hours after power on)
11.Photometric Mode : Absorbance, Transmission, Concentration
12.
13.Lamp-Interchange: Automatically change at user's preset wavelength
14.Monochromator : High Quality Blazed Holographic grating.1200L/mm
15.Detector: Photo Multiplier R928-40
16.Sample Compartment : 130x240x120mm, distance between light beams 100mm
17. Light Source : Socket halogen lamp and deuterium lamp(instrument does not need any manual adjustments after changing lamp)
Software:
1.Basic Measurement Mode: Photometric, Spectrum, Quantitation, Kinetics.
2.Photometric : Photometic measurement with result at single-wavelength and multi-wavelength of 10 wavelengths Max.
3.Quantitation : Quantitation of single-wavelength, two- wavelengths, three-wavelengths and derivative with multi- Point calibration curve ,1st to 4th order calibration curve regression.
4. Spectrum : Spectrum scan and arithmetic calculation, smoothing, 1st to 4th derivative,peakpick,point readout,range expanding.
5. Kinetics : Time scan of 10 wavelengths max. and arithmetic calculation,smoothing,1st to 4th derivative, peakpick, point readout, range expanding.
6.File-Function: Load and save of data file and parameter file
Double-Beam UV/Vis Spectrophotometer Phoenix-2200DPC

The Phoenix-2200DPC is the top of the range of our UV/Visible spectrophotometers. It is a Double-Beam Ratio Recording instrument with high performance and resolution thanks to its advanced optical system. It is a computer controlled spectrophotometer which comes with its dedicated UV-WIN Windows-based software for commanding the fuctions of the instrument and its accessories from a PC and for data collection and management.
We have recently introduced an identical model, the Phoenix-2200DPCV which has exactly all the same features as the above with a minor variation in the specifications whereas the bandpass is a fixed 2nm in the 2200DPC while it is variable in 6 values down to 0.1nm in the 2200DPCV. The price of the Phoenix-2200DPC is sensitively lower than the Phoenix-2200DPCV.
A wide and comprehensive range of accessories for routine and/or special applications is available upon demand. For further information, please apply to your nearest distributor or call our products specialists.
SPECIFICATIONS
Hardware
2. Spectral Bandwidth: Fixed at 2nm.
3. Wavelength Accuracy: +0.3nm(automatic wavelength correction)
4.Wavelength-Reproducibility: 0.1nm
5.Photometric Accuracy: +0.002Abs(0-0.5Abs), +0.004Abs(0.5- 1.0Abs), +0.3%T(0-100%T)
6.Photometric-Reproducibility: +0.001Abs
7.Stray Light : 0.02%(at 220nm 10g/l NaI aq.)
8.Baseline Flatness: +0.001Abs
9. Noise : < 0.0004Abs (at 500nm,with bandwidth 2nm)
10.Stability : 0.0004Abs (2 hours after power on)
11.Photometric Mode : Absorbance, Transmission, Concentration
12.
13.Lamp-Interchange: Automatically change at user's preset wavelength
14.Monochromator : High Quality Blazed Holographic grating.1200L/mm
15.Detector: Photo Multiplier R928-40
16.Sample Compartment : 130x240x120mm, distance between light beams 100mm
17. Light Source : Socket halogen lamp and deuterium lamp(instrument does not need any manual adjustments after changing lamp)
Software
1.Basic Measurement Mode: Photometric, Spectrum, Quantitation, Kinetics.
2.Photometric : Photometic measurement with result at single-wavelength and multi-wavelength of 10 wavelengths Max.
3.Quantitation : Quantitation of single-wavelength, two- wavelengths, three-wavelengths and derivative with multi- Point calibration curve ,1st to 4th order calibration curve regression.
4. Spectrum : Spectrum scan and arithmetic calculation, smoothing, 1st to 4th derivative,peakpick,point readout,range expanding.
5. Kinetics : Time scan of 10 wavelengths max. and arithmetic calculation,smoothing,1st to 4th derivative, peakpick, point readout, range expanding.
6.File-Function: Load and save of data file and parameter file